Sub-construction material

Test winner guarantees easy and fast reinforcement of thin material with risk of fracture.

- 2 mm white covering
- tested by "TÜV-Rheinland, section engineering
- fixing with instand adhesive
- grooves are not needed
- single sided bevel milling (10 mm) guaranties a perfect bonding into the edges

Experimental setup:
- Work piece 500 mm (Quarz Composite Stone), thickness of material 2 mm, reinforced with sub-construction material up to a total thickness of 30 mm.
- 4 pieces with sub-construction material of 4 different suppliers which were produced on the same way

Test result with Weha sub-construction material:
- break load without sub-construction material: 1,88 kilonewton
- break load with Weha sub-construction material: 4,11 kilonewton
- bend till fracture without sub-construciton material: 1,3 mm
- bend till fracture with Weha sub-construction material: 5 mm

Test piece with Weha sub-construction material was winner in both test categories.